Posted by Dodgeman on December 23rd, 2001 06:09 PM
In reply to Have an electrical question by Steve: on December 23rd, 2001 01:12 PM [Go to top of thread]

To wire for the generator is to install a generator switch after the switch to your workroom. The generator switch will either make it possible to power your workroom from your house power OR from your generator, but it will be impossible to make a mistake and accidentally backfeed to the house. You have the right idea to isolate the generator, but it must be done in a way to make it foolproof. Check with your local building/electrical inspector if you have questions.
Happy Holidays!