In reply to some answers by Moderator, Steve on July 13th, 2002 08:28 PM [Go to top of thread]

I have installed a lot of T1-11 on many different projects,many different builders,and never have used screws.2 1/2" ring shank splitless zinc coated(Maze double dipped)nails will do the job if as Steve said you hit the studs,especially on the seams.Z flashing a must on any horizontal break.You could use screws if you have the time and extra $$$ but heck you could use screws to put roof shingles or vinyl siding on but why would you?The only problem I have seen with T1-11 is woodpeckers.If there are any voids in the plys in the siding there is a good chance some have larve in them and the woodys will find them.Depends where you live though.Home inspector huh,....I'm not going there.Luck

Was this post helpful? Yes: or No:

Topic History:

Topic Follow-ups:

  • I agree with Scott by Moderator, Steve  7/14/02 10:55 AM
  • t1-11 by stacy  1/31/03 07:51 PM
  • T1-11 by Mike Strong  3/9/03 03:04 PM (: 2, : 0)