Posted by Raymond VinZant Plumbing Prof on December 11th, 2002 11:01 AM
In reply to missing information by Harold on December 10th, 2002 07:31 PM [Go to top of thread]

I would check to see if the air has been blead out of the system. Typically each radiator will need this once a season. Every time you put water into the boiler to refill the system to at least 12 psi, the water carries with it a certain amount of air. This air needs to be removed as it stratifies in the radiator. Each radiator has a bleed valve on the radiator.
Good Luck
Master Plumber