Posted by Michelle Neff on January 29th, 2003 09:59 PM
In reply to PAYNE FURNACE by GARY on January 25th, 2003 07:26 PM [Go to top of thread]


What happens durring that heat call?

does it gain a burn at all?

Check the door switch on the blower compartment. The paynce can be a pain in the butt when that door moves a little bit out of whack, the test is too push on it durring a no start heat call if it lives that sicth misght need to be relaced or moved a little to insure contact closure when the fan door is closed.

If you get a shiort cycle burn then its a flame sensor that isnl;t seeing the flame.
By the way it a is a rare thing.

Was this post helpful? Yes: or No: