LENNOX CONSERVATOR III


Posted by RDSETT on September 20th, 2007 06:34 PM
In reply to Lennox G16R Furnace (pilot and igntition - no main gas?) by Chris W on January 5th, 2003 12:53 PM [Go to top of thread]

2 of 5 people found this post helpful

IF YOU HAVE A CONSTANT CLICKING SOUND OR IT LIGHTS AND THEN QUITS...TAKE OF THE CENTER SHEET METAL SHROUD AND YOU WILL SEE METAL FIXTURE ON THE LEFT SIDE,, THIS IS HAS A DIAGHRAM IN IT AND DETECTS THE LOW PRESSURE SIDE WHILE THE FAN IS BLOWING,, TAKE OFF THE 2 HOSES ,,,MAKE SURE YOU MARK THEM... AND SEE IF THERE IS ANY CONDENSATE WATER IN THEM,,, IF SO DRAIN OR BLOW OUT AND RECONNECT,, IT SHOULD NOW RUN,,,YOU MAY NEED A NEW DIAPHRAM.... I DONT KNOW HOW THE CONDENSATE GETS IN THERE.