There are a couple of things I would suggest. First check the air filter that it is clean. If you have air conditioning try putting the unit into heat and then put the fan selector from auto to on, this will kick the fan into a higher fan speed, which may deliver more air to the bath. Also check to be sure the bath room duct branch does not have a closed manual damper. Third be sure that your cold air return opening is not blocked at all.